Solar MET Station and Pyranometer

Data Acquisition Systems & MET Stations

Flawed pyranometer data ruins performance modeling. We mount, wire, and verify sensors so your plant's telemetry is bulletproof.

Sensor integrity

Bad weather data means bad revenue models.

A MET station isn't a pole with sensors. It is the baseline for your plant's performance ratio. If irradiance drops, or BoM temperature drifts, your O&M analytics are useless — and so is the case you make to lenders at refi.

We specify, mount, wire, and verify the full instrument stack. OEM calibration sheets follow the asset — every sensor traceable, every reading defensible.

±2.0%

Class A pyranometer accuracy

IEC 61724-1

Performance monitoring standard

  1. 10m POA

    Class A Pyranometer

    Hukseflux SR30 · spectrally flat

    285–3000 nm · ±2.0% accuracy · ventilated heated dome

  2. 10m AGL

    Anemometer + Vane

    NRG #40C · class 1.0

    1–96 m/s · ±0.1 m/s · 360° vane resolution

  3. 2m AGL

    Ambient Temp + RH

    Vaisala HMP155

    −80…+60°C · ±0.176°C · capacitive HUMICAP

  4. Module

    Back-of-Module Temp

    PT-100 1/3 DIN · adhesive

    4 sensors per array · centred on module · BoM mapped

  5. 1.5m AGL

    Albedo Sensor

    Apogee SP-510 (up + down)

    Bifacial-aware · 0.05 albedo resolution

Ground · concrete pier foundation

Hand-over package

Defensible data from day one.

Every sensor traceable to the OEM cert sheet. Every analog signal verified on the Modbus map. Every mast erected to spec.

Calibration Certificates

OEM-issued calibration sheets for every Class A pyranometer, anemometer, and temperature sensor — tracked, archived, and handed over to the asset owner.

Point-to-Point Validation

Every analog signal walked from the sensor terminal to the Modbus register on the ISO portal. Sign-offs on the SAT checklist. No surprises during witness testing.

Mast & Mounting

Rigid mast erection and cross-arm mounting prevents wind-induced vibration noise on irradiance readings. Pier foundations sized to your geotech, sensors clear of array shading.

  • Class A pyranometer (POA + horizontal)
  • Back-of-module temperature
  • Albedo for bifacial arrays

Frequently Asked Questions

Yes, we specify, supply, and build the entire DAS hardware package. We utilize industry-standard sensors (Kipp & Zonen, Hukseflux, Apogee) integrated with our RenergyWare panels.
We prefer the EPC to handle the concrete foundation based on our specs, and then we erect the mast, mount the instruments, and wire the sensors back to the RTU.

Guarantee your performance baseline.

Ensure your capacity testing succeeds with perfectly mapped MET stations.

Call UsConsultSubmit RFP